parameter-monitor.toml: Parameter Monitor Settings#
- parameter-monitor.toml#
Parameter Monitor configuration.
This configuration defines the juice parameters to monitor for throttling and their thresholds.
- juice_topic_monitoring_units#
Type:
dict[string, object].Dictionary of Juice Topic Monitor units.
The key is the unique identifier for the unit, and the value is the configuration for that unit.
- juice_topic_monitoring_units.{key}#
Type:
object.Base monitoring configuration for individual units.
Defines a topic and field to monitor, and thresholds for warning and throttling.
- juice_topic_monitoring_units.{key}.display_label#
Type:
string.Human-readable description to display in the UI.
- juice_topic_monitoring_units.{key}.unit#
Type:
string. Default:'1'.Unit that the value is measured in. Must be compatible with
pint.Unit().Defaults to dimensionless unit.
- juice_topic_monitoring_units.{key}.monitored_topic#
Type:
string.Juice topic to subscribe for monitoring the unit.
- juice_topic_monitoring_units.{key}.monitored_event_type#
Type:
string.Type of the event to monitor.
This should be the full module path of the event class, e.g.
orangeqs.juice.system_monitor.data_structures.TemperaturePoint.The field specified in
monitored_fieldshould be present in the data of this event.
- juice_topic_monitoring_units.{key}.monitored_field#
Type:
string.Field in the topic data to monitor.
- juice_topic_monitoring_units.{key}.warn_if_larger#
Type:
number | null.Warn users if the unit is above a certain value.
- juice_topic_monitoring_units.{key}.throttle_if_larger#
Type:
number | null.Pause executing experiments if the unit is above a certain value.
- juice_topic_monitoring_units.{key}.throttle_grace_interval#
Type:
number. Default:0.0.Interval between detection of throttled state and actually throttling.
This value can be used if the value can fluctuate. If it is set to non-zero time, system will monitor value for that time to ensure that system should be throttled.
- juice_topic_monitoring_units.{key}.stop_throttle_if_smaller#
Type:
number | null.Resume executing experiments if the unit is below a certain value.
In general, this value should be less than
throttle_if_larger. For example, if we are running equipment that is constantly heating up under the load and throttle at 90°C, it may be wise to wait until it cools down to 80°C before resuming experiments.If
throttle_if_largeris specified,stop_throttle_if_smallerwill be set to the same value by default. Ifstop_throttle_if_smalleris larger thanthrottle_if_larger, settings won’t pass validation.
- juice_topic_monitoring_units.{key}.stop_throttle_grace_interval#
Type:
number. Default:0.0.Interval between detection of safe state and actually resuming.
This value can be used if the value can fluctuate. If it is set to non-zero time, system will monitor value for that time to ensure that system should be resumed.